Turbine Flow Meter vs. Vortex Flow Meter
Working Principle
Turbine: Fluid rotates a turbine, with speed proportional to flow rate, detected by magnetic sensors.
Vortex: Based on Kármán vortex street, fluid creates vortices past a bluff body, with frequency related to flow rate.
Suitable Media
Turbine: Only clean, low-viscosity liquids (e.g., water, diesel) or gases.
Vortex: Can measure liquids, gases, steam; handles high temperature/pressure and particulate matter.
Accuracy & Maintenance
Turbine: High accuracy (±0.5%~1%) but requires regular lubrication/cleaning.
Vortex: Slightly lower accuracy (±1%~2%), low maintenance, no moving parts.
Installation & Cost
Turbine: Requires horizontal installation, high straight-pipe needs, low initial cost but higher maintenance.
Vortex: Flexible installation, vibration-resistant, lower long-term cost.
How to Choose?
Turbine: High precision, clean media, and maintenance-permitted scenarios (e.g., oil, chemical).
Vortex: Complex media (particles, high temp/pressure), low maintenance, or space-limited scenarios.