️ I. Core Functional Differences
Feature Piston Flow Switch Electromagnetic Flow Meter
Primary Function Detects if flow reaches preset threshold; outputs switching signal (ON/OFF) Measures flow value precisely; outputs continuous signal (e.g., 4-20mA, pulse)
Signal Type Binary signal (relay contact, NPN/PNP) Analog or digital signal (instantaneous/totalized flow)
Typical Application Pump start/stop control, dry-run alarm, safety interlock Process optimization, energy analysis, trade settlement
Accuracy Lower (±5%–±10%) High (±0.1%–±0.5%)
🔧 II. Working Principle Comparison
Piston Flow Switch
Mechanical Trigger: Fluid drives an internal magnetic piston, actuating an external reed switch to open/close.
Compatible Media: Liquids/gases (low particulate), high-viscosity fluids (e.g., lubricating oil).
Electromagnetic Flow Meter
Electromagnetic Induction: Based on Faraday’s law; conductive fluid cutting magnetic field generates voltage proportional to flow velocity.
Media Limitations: Only for liquids with conductivity ≥5μS/cm (e.g., water, acids/alkalis); incompatible with oils/gases.
📊 III. Key Technical Parameters
Parameter Piston Flow Switch Electromagnetic Flow Meter
Response Time Fast (milliseconds) Slower (seconds)
Turndown Ratio Narrow (1:5–1:10) Wide (1:20–1:50)
Pressure Drop Very low (≤0.3 Bar) Moderate (pipe-size dependent)
Pressure Rating Up to 100 Bar (SS housing) Typically ≤40 Bar
🏭 IV. Typical Application Scenarios
Piston Flow Switch Applications
Fire pump control: Activates pump when flow ≥20% setpoint.
Compressed air systems: Gas flow anomaly alarms.
Electromagnetic Flow Meter Applications
Wastewater plants: Precise flow measurement/billing.
Chemical processes: Corrosive media monitoring (e.g., acids/alkalis).
️ V. Key Selection Considerations
Piston Flow Switch
Vertical installation requires upward flow only to prevent piston sedimentation.
Install ≥80-mesh filter to avoid debris jamming.
Electromagnetic Flow Meter
Full-pipe requirement: Incomplete filling or air bubbles cause measurement failure.
Avoid strong EMI: Motors/transformers disrupt magnetic field accuracy.
Summary: Piston flow switches are cost-effective on-off controllers for simple start/stop logic; electromagnetic flow meters are high-precision instruments for conductive liquid metering.
Key Terminology:
量程比 → Turndown ratio
干簧管 → Reed switch
法拉第定律 → Faraday’s law
电导率 → Conductivity
满管要求 → Full-pipe requirement
电磁干扰 → EMI (Electromagnetic Interference)