Welcome,Flow Switches,Shanghai ZanKe Automation Technology Co., Ltd Hotline:18001874240
Language: Chinese∷  English

Home> English Website news

Ultrasonic Flowmeter Accuracy Analysis

Time: 2025-07-30 02:07:53 Click:0

Here is the professional English translation of the ultrasonic flowmeter accuracy analysis:


Ultrasonic Flowmeter Accuracy Analysis


The measurement accuracy of ultrasonic flowmeters typically ranges from ‌±0.5% to ±2.5%‌, influenced by operational conditions and application requirements ‌. Key details are summarized below:


1. Accuracy Classifications

High Precision (Class 0.5)‌:

Error range: ‌≤±0.5%‌

Applications: Custody transfer, pharmaceuticals, and other high-demand scenarios. Requires annual calibration ‌.

Portable devices support field calibration via magnetic probes ‌.

Industrial Standard (Class 1.0)‌:

Error: ‌≤±1%‌

Applications: Core water treatment processes, chemical industry. Requires straight pipe sections (10D upstream, 5D downstream; D=pipe diameter) ‌.

General Purpose (Class 1.5+)‌:

Error: ‌≤±1.5%‌

Applications: Wastewater monitoring, non-critical data collection. Lower maintenance costs ‌.

2. Critical Factors Affecting Accuracy

Installation Conditions‌:

Insufficient straight pipe sections (upstream <10D) or disturbances from valves/bends increase errors ‌.

Sensor misalignment or dried coupling gel attenuates signals ‌.

Fluid Properties‌:

Transit-time method‌: High accuracy for pure water (±0.5%~1%); exceeds ±2% with bubbles/impurities ‌.

Doppler method‌: Relies on suspended particle concentration; ineffective for low-impurity fluids ‌.

Environmental Interference‌:

EMI, temperature extremes (beyond -30℃~160℃), or pipe vibration require compensation ‌.

Parameter Configuration‌:

Improper damping coefficient (e.g., excessive value causing response delay) impacts dynamic accuracy ‌.

3. Accuracy Reference for Typical Applications

Scenario‌ ‌Recommended Class‌ ‌Primary Error Sources‌

Tap Water/Heating Systems Class 1.0 Water temp. variation, pipe scaling ‌

Industrial Wastewater/Slurries Class 1.5~2.5 Suspended solids, turbulent flow ‌

Oil/Fiscal Metering Class 0.5 Medium density fluctuations ‌

Open-Channel Flow Monitoring Class 1.5~2.5 Water level variation, weir type ‌


Maintenance Recommendations‌:


Quarterly sensor inspections; annual calibration.

Doppler method preferred for particle-laden fluids; transit-time method for clean fluids ‌.


Note: All technical terms (e.g., transit-time/Doppler method, damping coefficient) and numerical references (^^n^^) align precisely with the original Chinese content.